110c Thermostats

110c Thermostats

Part: 110c thermostat


Purpose: A thermostat is a safety feature that cuts power to the element if the thermostat is tripped by overtemp. The thermostat is tripped by sensing direct heat contact with boiler.


Slayer upgraded the brew tank thermostat from 98c to 110c. The 98c thermostats had a variance which could cause a trip at brewing temperatures and not send voltage to the element causing a drop in temperature of the group. The new thermostats are rated 110c and, thus, will not trip at brewing temperatures.


Replacing 110c Thermostat

Turn machine off at power source
Remove cup tray and set aside
Remove screws holding top panel and set aside
Locate thermostat on the neck of the brew boiler
Remove the terminals from the thermostat
Unscrew with your fingers and remove
Screw in the new thermostat finger tight
If the thermostat is over tightened there is a risk of breaking the part in the tank
Reattach terminals




    • Related Articles

    • PID Basic Settings - V3

      PID Basic Settings - Espresso V3 SLAYER recommends all service be performed by an experienced SLAYER Espresso trained technician. For a technician reference near you, please contact SLAYER Support at (206)-284-7171 (#1 in Directory) or email ...
    • Blending Hot Water Mix Valve - V3

      Adjusting Hot Water Spout Temperature: Espresso V3 SLAYER Espresso V3 machines feature a hot water mix valve which blends low pressure (line pressure) inlet water with hot (steam tank) water. The mix valve is a 24vDC solenoid valve and is activated ...
    • Error Code Identification - Steam Series

      Steam X, EP, & LP Error Code Identification Error codes replace the temperature and/or pressure value (observed on the display) of the faulted circuit. Brew Circuit AL1: Group temp probe (thermistor) is interrupted or disconnected. Disables group's ...
    • Replacing High Limit Switch (limit thermostat)

      Tools Needed: #2 screwdriver Time Needed: Less than 10 minutes Remove top front panel Remove wires from high limit switch Remove the high limit switch. The high limit switch is a brass fitting that screws into stainless steel. It is very fragile and ...
    • Error Code Identification - Steam Single

      Steam Single Error Code Identification 015 - Reservoir Low Water Level Machine software detected a condition of low water level in the reservoir. 016 - Brew Actuator Position Error Software detected an electronics failure of actuator switch contact. ...