Adjusting Brew Temp Offset Single Group

Adjusting Brew Temp Offset Single Group

Tools Needed: Scace

Warm up your Scace. Best way is to leave it engaged in the group head and run 30 second cycles. Keeping in mind we are running cold water into the boiler when brewing, so the more frequently you run the cycle the lower the temp will go. Best practice is to run a 30 second cycle and wait one minute. Run 5 cycles to heat up the Scace. 

Attach connect your multi meter for your thermometer reading. 

  1. Run a 30 second water cycle in full brew. Turn the group off.  Note the temp right before turning off group.
  2. Press the circle to enter programming
  3. Scroll to advanced programming
  4. Press Circle to enter
  5. Scroll to brew temp offset. 
  6. Press circle to enter
  7. You'll see the temperature listed that the machine is currently assuming. 
  8. If your scace temp is higher than the machine temp, increase the offset. The number does not correlate to any degree value, it is simply a reference point.
  9. Return to step 1 and repeat the cycle 3 times. 
Your ultimate goal is to get your scace reading and the machine reading within 1-2 degree's F of each other or .1 - .15 C




    • Related Articles

    • Error Code Identification - Single Group

      Single Group Errors STEAM FILL: Fill routine has run for ten minutes without detecting water. Will not allow machine to heat and will turn off the steam heater. Unit will need to be reset and water is detected. Check water feed to machine for flow. ...
    • Single Group Internal Diagram

      1. 3-Way Brew Solenoid 8. Vacuum Breaker 2. Needle Valve 9. Pressure Relief Valve 3. Inlet (Autofill) Solenoid 10. Brew Gauge 4. Steam Valve 11. Expansion Valve 5. Hot Water Valve 12. Steam Tank Ball Valve, Drain 6. Transducer 13. Brew Tank Ball ...
    • Single Group Electronics Identification Diagram

      2020 Single Group 1. Display Ribbon Cable 7. Group Cap Magnet Switches 2. Relay Harness 8. Steam Tank Level Probe 3. 24v DC Power 9. Transducer 4. Pump 10. SSR Steam Relay 1 5. Solenoids 11. SSR Steam Relay 2 6. Brew Tank RTD 12. SSR Brew Relay If ...
    • Hard Reset - Single Group

      Hard Reset, Single Group Step 1: Press circle to enter programming Scroll to Advanced Settings and circle to enter Scroll to menu option Save/Restore settings, press circle to enter Arrow up to Reset Factory Default Press circle, arrow to yes, press ...
    • Single Group (Classic) Electronics Identification Diagram

      Single Group Classic Electronics Diagram Slayer Single Groups manufactured before January 2020. 1. Display Ribbon Cable 7. Group Cap Magnet Switches 2. Relay Harness 8. Steam Tank Level Probe 3. 24v DC Power 9. Transducer 4. Solenoids 10. SSR Steam ...