Error Code Identification - Steam Single

Error Code Identification - Steam Single



Steam Single Error Code Identification



  1. 015 - Reservoir Low Water Level
    1. Machine software detected a condition of low water level  in the reservoir. 
  2. 016 - Brew Actuator Position Error
    1. Software detected an electronics failure of actuator switch contact.
  3. 051 - Steam Pressure Sensor
    1. Detected an out-of-range value for steam tank pressure sensor.
  4. 052 - Time Out Heater activation, Steam Tank
    1. Steam tank heating timeout has been reached even if the steam pressure is still under the setpoint.
  5. 058 - Steam Tank Overpressure
    1. Steam tank pressure has exceeded 1.85 bar.
  6. 059 - Steam Tank Refill Time Out
    1. Steam tank refill timeout has been reached even if the pump and solenoid valved are activated in order to refill the steam tank.
  7. 060 - Steam Tank Water Level Sensor Fault
  8. 151 - Brew Temp Sensor 
    1. Machine software detected an out-of-range value for brew tank temperature sensor.
  9. 152 - Time Out Heater Activation, Brew Tank
  10. 159 - Brew Tank Fill Error
    1. Brew tank not filling properly due to missing feedback from the flowmeter.
  11. 166 - Missing Water During Extraction, Automatic Mode
    1. Automatic extraction not properly completed due to missing feedback from the flowmeter.
AlertSLAYER recommends all service be performed by an experienced SLAYER Espresso trained technician. For a technician reference near you, please contact SLAYER Support at (206)-284-7171 (#1 in Directory) or email support@slayerespresso.com.



Questions or concerns? Please contact support@slayerespresso.com

    • Related Articles

    • Error Code Identification - Espresso Single Group

      Espresso Single Group Error Code Identification SLAYER Espresso Single Group error codes correlate directly to the affected hydraulic or electrical circuit. Error codes help isolate further troubleshooting measures. When present on the display, error ...
    • Error Code Identification - Steam Series

      Steam X, EP, & LP Error Code Identification SLAYER Steam Series feature error codes which correspond to the affected hydraulic or electrical circuit. There error codes help isolate further troubleshooting measures. Error codes replace the temperature ...
    • E015 Fill Error - Steam Single

      Troubleshooting <Fill Reservoir> - Steam Single Known Issue: SLAYER Steam Single reservoir indicator float is not indexing properly with the reed switch assembly. Resulting in an E015 Fill Error. SLAYER Steam Single Error Codes Symptoms: Machine does ...
    • Error Code Identification - Love Controller

      Espresso V3 Love Control Errors SLAYER recommends all service be performed by an experienced SLAYER Espresso trained technician. For a technician reference near you, please contact SLAYER Support at (206)-284-7171 (#1 in Directory) or email ...
    • Single Group (Classic) Electronics Identification Diagram

      Single Group Classic Electronics Diagram Slayer Single Groups manufactured before January 2020. 1. Display Ribbon Cable 7. Group Cap Magnet Switches 2. Relay Harness 8. Steam Tank Level Probe 3. 24v DC Power 9. Transducer 4. Solenoids 10. SSR Steam ...