- 015 - Reservoir Low Water Level
- Low water level in reservoir
- 016 - Brew Actuator Position Error
- Software detected an electronics failure of actuator switch contact.
- 051 - Steam Pressure Sensor
- Detected an out-of-range value for steam tank pressure sensor.
- 052 - Time Out Heater activation, Steam Tank
- Steam tank heating timeout has been reached even if the steam pressure is still under the setpoint.
- 058 - Steam Tank Overpressure
- Steam tank pressure has exceeded 1.85 bar.
- 059 - Steam Tank Refill Time Out
- Steam tank refill timeout has been reached even if the pump and solenoid valved are activated in order to refill the steam tank.
- 060 - Steam Tank Water Level Sensor Fault
- 096 - Maintenance Overdue
- 151 - Brew Temp Sensor
- Machine software detected an out-of-range value for brew tank temperature sensor.
- 152 - Time Out Heater Activation, Brew Tank
- 159 - Brew Tank Fill Error
- Brew tank not filling properly due to missing feedback from the flowmeter.
- 166 - Missing Water During Extraction, Automatic Mode
- Automatic extraction not properly completed due to missing feedback from the flowmeter.