Heli Coil for Steam Tank High Limit Replacement

Heli Coil for Steam Tank High Limit Replacement




Helicoil repair for damaged threads on Steam tank High Limit. 

Tools Needed:
M4x/0.7 Helicoil Kit
11/64 Stainless Steel Drill Bit
Metal cutting Lube
Drill
Center punch

Link to where we sourced the product. 

Use center punch to create a divot in the sheered off stem inside the tank.

Gauge the depth needed to drill by marking off with tape on the drill bit.
Only drill as deep as the high limit housing.

Using the drill bit, slowly drill out the hole.

Use the Helicoil kit instructions to clean, re-thread, and insert the Helicoil

Add a small application of thermal paste to the base and threads of the High Limit Thermostat.

Install finger tight.

Questions or concerns? Please contact: support@slayerespresso.com
    • Related Articles

    • Checking Steam Tank High Limit Single Group

      Checking Steam Tank High Limit Single Group Tools Needed: Multimeter, #2 screwdriver Time Needed: 10 min Turn off machine and unplug from power Remove cup tray Remove front top panel Remove leads to high limit Check continuity between the poles View ...
    • Replacing High Limit Switch (limit thermostat)

      Tools Needed: #2 screwdriver Time Needed: Less than 10 minutes Remove top front panel Remove wires from high limit switch Remove the high limit switch. The high limit switch is a brass fitting that screws into stainless steel. It is very fragile and ...
    • Changing Brew Element, Steam Series

      Step 1: Remove top front panel and lower front panel  1. Turn off the main breaker (high voltage) and main power switch (main power, covered by rubber gasket). Unplug the power cord from the wall. Turn off water at water source. 2. Remove the cup ...
    • Testing High Limit Switch on Brew Tank, Universal

      Time Needed: 5 Minutes Tools Needed: Multimeter, Screwdriver Parts Needed: Thermostat, 110C 30000-20251 Need to purchase these parts? Download the pre-filled order form and submit a ticket with the PDF attached.  Step 1: Remove cup tray. Step 2: ...
    • Replacing Transducer Assembly, Single Group Classic

      Slayer Single Group (Classic) transducer replacement UPDATE: Honeywell transducers have been phased out. Please click here for updated instructions. If you still have new legacy Honeywell transducers on hand, see below for replacement instructions. ...