Portafilter Head Replacement
Portafilter Handle Removal Procedure
Install portafilter into the group head
Grip the handle tightly and rotate in a counter clockwise direction
Remove old portafilter head from group
Install new portafilter head
Install the new portafilter handle into the portafilter head rotating in a clockwise direction.
Related Articles
Replacing Group Head Gasket - Universal
Replacing Group Head Gasket Objective: Replace group head gasket per Slayer's recommended Preventative Maintenance schedule. All SLAYER Espresso machines and Preventative Maintenance Kits feature 58mm x 6.1mm EPDM group head gaskets. Parts: ...
Replacement of RTD, Espresso Line
Replacement of RTD Espresso Line Tools Needed: Philips Screwdriver, 12mm Wrench, Teflon Tape Time Needed: 30min Shut off water Turn off power Remove screws on group cover Remove Group Cover The RTD has the white wire running off of it Follow the ...
Replacing Transducer Assembly, Single Group Classic
Slayer Single Group (Classic) transducer replacement UPDATE: Honeywell transducers have been phased out. Please click here for updated instructions. If you still have new legacy Honeywell transducers on hand, see below for replacement instructions. ...
Replacement of SSR on Power Supply V3
Replacement of SSR on Power Supply V3 Tools Needed: #2 Philips Head Screwdriver, Large flat head screwdriver, Needle nose pliers, 2 x 7/16" wrenches. Time Needed 30-45 minutes. 1. Verify the incorrect relay's are on the power supply. 2. Remove the ...
Wing Replacement, Steam Series
Wing Replacement Time Needed: 1 hour Tools Needed: #10 allen wrench, 10mm socket driver, Torque wrench set to 40 ft pounds, #1 phillips head screw driver Shut down machine and turn off water, disconnect from power Elevate machine, We use a 1x6 ...