Replace Pre-Infusion Solenoid Slayer Steam LP
Replace Pre-Infusion Solenoid Slayer Steam LP
Time Needed: :30min - 1:00hr
Tools Needed: Adjustable wrench, #2 screw driver.
Turn off the machine, unplug from power source.
Turn off water.
Open Drain Line for group being worked on
Remove the boot to the solenoid
Loosen nut on pre infusion tube
Loosen nuts on the water tubes to the assembly
Remove and replace assembly.
Related Articles
Pre-Infusion Solenoid Troubleshooting - Steam LP
Pre-Infusion Solenoid Troubleshooting - Steam LP SLAYER recommends all service be performed by an experienced SLAYER Espresso trained technician. For a technician reference near you, please contact SLAYER Support at (206)-284-7171 (#1 in Directory) ...
Error Code Identification - Steam Series
Steam X, EP, & LP Error Code Identification SLAYER Steam Series feature error codes which correspond to the affected hydraulic or electrical circuit. There error codes help isolate further troubleshooting measures. Error codes replace the temperature ...
Slayer Board Wiring - Steam Series
Control board wiring diagrams for Slayer Steam Series. These schematics can be used for identifying control inputs and for reference when replacing the board. *Steam X board wiring can be referenced by the Steam EP drawing.* Questions identifying a ...
Program and Calibrate Volumetrics - Slayer Steam X
Program and Calibrate Slayer Steam X Volumetrics Time: 10 minutes Tools: Espresso Scale Preparation: Calibrating volumetrics requires considerate espresso preparation. External factors such as coffee, dose, and tamp equally contribute to the quality ...
Record & Playback Volumetrics - Steam LP
Program, Calibrate, & Troubleshoot Steam LP Volumetrics Quickly and easily 'Record' your last manual shot and 'Replay' it all day. Objective: Create and save recipes using Manual Mode and the Record & Playback feature. During the 'Recording' process, ...