Time Needed: 10-15 Minutes

Parts Needed:

46000-50140 Vacuum Breaker/ Anti-Suction Valve
46000-50130 Gasket for Vacuum Breaker/Anti-Suction Valve
Need to purchase these parts? Download the pre-filled order form and submit a ticket with the PDF attached. 

Tools Needed:

Small Adjustable Wrench




Step 1: Unplug machine from power source


Step 2: Remove cup tray from machine


Step 3: Use adjustable wrench to remove vacuum breaker, making sure the wrench is level with the vacuum breaker. If the wrench is used at an angle, there is risk in breaking the fitting. 



Step 4: Wrap the new vacuum breaker in 3 wraps of Teflon tape



Step 5: Install new vacuum breaker hand tight


Step 6: Tighten vacuum breaker with wrench a half turn or until resistance


Step 7: Turn on machine and look for leaks around the vacuum breaker. If the vacuum breaker is leaking, tighten slightly with a wrench. 



    • Related Articles

    • Preventative Maintenance and Cleaning Procedures, Single Group

      Single Group Cleaning and Preventative Maintenance Cleaning and Preventative Maintenance (PM): What is preventative maintenance and how does it differ from changing major parts? Similar to changing the oil in your car, PM is routine maintenance to ...
    • Disassembly of Vacuum Breaker and Inspection of Internal Seat

      Disassembly of Vacuum Breaker and Inspection of Internal Seat Time Needed: 30 Min Tools Needed: Two Crescent Wrenches ​ Warning: Turn off machine and purge the steam before completing this action. Once Steam is purged and vacuum breaker has fallen, ...
    • Replacing Expansion Valve - Single Group

      Replacing Expansion Valve on Single Group (Pre-2023) Objective: Expansion valves should be replaced as part of your preventative maintenance cycle. The style on the Single Group is pre-set to 11bar, but can occasionally require adjustment or ...
    • Panel Installation - Single Group

      Single Group Panel Installation Slayer recommends that all service be performed by an experienced Slayer Espresso trained technician. Objective: Install and remove panels for maintenance, service, and panel replacement. Please contact Slayer Tech ...
    • ECR 22030 - Single Group Side Block

      Please see PDF attached for details on changes with the Single Group side blocks.