Replacing Circuit Board Single Group

Replacing Circuit Board Single Group

Replacing Circuit Board Single Group
 

Tools Needed: #2 phillips head screw driver, #0 phillips head screw driver.



Time Needed: 10 minutes

Unplug machine and turn off water

Remove Cup Tray


Remove the two screws on the back panel under where the cup tray sits. Remove the panel being careful of the Ribbon Cable. Disconnect the ribbon cable


Remove the connectors, take a picture for reference when replacing. 


Remove 4 screws, one on each corner of the board, remove board. 


Replace new board in the same operation. 
    • Related Articles

    • Testing No Power, Single Group

      Testing No Power, Single Group Time Needed: 10 Minutes Parts Needed: None Tools Needed: #2 Phillips Screwdriver Multi Meter Circuit Board Reference #1 - Main power - 24v DC from power supply #2 - Relay #3 - Display ribbon cable #4 - Transducer #5 - ...
    • Single Group (Classic) Electronics Identification Diagram

      Single Group Classic Electronics Diagram Slayer Single Groups manufactured before January 2020. 1. Display Ribbon Cable 7. Group Cap Magnet Switches 2. Relay Harness 8. Steam Tank Level Probe 3. 24v DC Power 9. Transducer 4. Solenoids 10. SSR Steam ...
    • Diagnosing SSR Single Group

      Diagnosing SSR Single Group Tools Needed: Voltage meter Remove cup tray and back panel of the machine, being aware of the ribbon cable attached to the control board. Leave the ribbon cable attached and lean the back panel on the machine giving you ...
    • ECR 22030 - Single Group Side Block

      Please see PDF attached for details on changes with the Single Group side blocks. 
    • RTD Test, Single Group

      RTD Test, Single Group This procedure tests the resistance of the RTD. The RTD measures the temperature of the brewing group. As the machine fluctuates in temperature, the resistance will change sending a signal to the board to heat or not heat the ...