Reset Factory Default - Steam Series
Reset Factory Default - Steam X, LP, & EP
SLAYER recommends all service be performed by an experienced SLAYER Espresso trained technician. For a technician reference near you, please contact SLAYER Support at (206)-284-7171 (#1 in Directory) or email support@slayerespresso.com.
Restoring factory default will reset all personal settings. Scroll through the menu settings and record the below information:
- Programed Recipes
- Brew Group Temperature Settings & Offsets
- Flowmeter Offsets
- Date & Time
- Power Save Schedules
Hard Reset
Step 1:
- Scroll to Switch Off.
- Press encoder, scroll to <YES> and select.
- Display will show OFF and the time.
From this menu, press and hold the encoder for 10 seconds to enter the deep menu.
Record following information:
- Serial Number
- Steam LP: FlowMeterRateG
Scroll to Exit Menu. Press the encoder.

You're now ready to reset the machine.
Step 2:
- Turn OFF voltage breaker.
- Turn OFF main power rocker switch.
- Turn ON the main power rocker switch while simultaneously pressing down the encoder knob and hot water button until the Group 1 display reads Preset Done.
- Release the buttons.
- Power cycle using main power rocker switch.
- Upon power cycling the machine. Group 1 will briefly prompt the firmware version and a blank serial number.
Step 3:
Re-enter the information:
- Serial Number
- Number of Groups
- Brew Temperature Offsets
- Flowmeter Offset
- Steam LP: FlowMeterRate G
Questions or concerns? Please contact: support@slayerespresso.com
Related Articles
Password Reset - Steam Series
Password Reset - Steam LP & EP Steam Single Technician Menu Password: 80000 Advanced Menu: Steam LP: 7 7 7 7 7 7 7 (seven 7's) Steam EP: SEATTLE7 Default Password: Manager - 1 1 1 1 Advanced - 1 2 3 4 Step 1: From the Menu press the encoder knob to ...
Hard Reset - Single Group
Hard Reset, Single Group Step 1: Press circle to enter programming Scroll to Advanced Settings and circle to enter Scroll to menu option Save/Restore settings, press circle to enter Arrow up to Reset Factory Default Press circle, arrow to yes, press ...
Slayer Board Wiring - Steam Series
Control board wiring diagrams for Slayer Steam Series. These schematics can be used for identifying control inputs and for reference when replacing the board. *Steam X board wiring can be referenced by the Steam EP drawing.* Questions identifying a ...
Flowmeter Not Reading Output - Steam Series
Flowmeter Not Reading Output - Steam Series SLAYER recommends all service be performed by an experienced SLAYER Espresso trained technician. For a technician reference near you, please contact SLAYER Support at (206)-284-7171 (#1 in Directory) or ...
Eltek Transducer Retrofit - Steam Series
Technician's retrofit guide for Steam Series. SLAYER recommends all service be performed by an experienced SLAYER Espresso trained technician. For a technician reference near you, please contact SLAYER Support at (206)-284-7171 (#1 in Directory) or ...