Reset Factory Default - Steam X, LP, & EP
SLAYER recommends all service be performed by an experienced SLAYER Espresso trained technician. For a technician reference near you, please contact SLAYER Support at (206)-284-7171 (#1 in Directory) or email support@slayerespresso.com.
Restoring factory default will reset all personal settings. Scroll through the menu settings and record the below information:
- Programed Recipes
- Brew Group Temperature Settings & Offsets
- Flowmeter Offsets
- Date & Time
- Power Save Schedules
Hard Reset
Step 1:
- Scroll to Switch Off.
- Press encoder, scroll to <YES> and select.
- Display will show OFF and the time.
From this menu, press and hold the encoder for 10 seconds to enter the deep menu.
Record following information:
- Serial Number
- Steam LP: FlowMeterRateG
Scroll to Exit Menu. Press the encoder.

You're now ready to reset the machine.
Step 2:
- Turn OFF voltage breaker.
- Turn OFF main power rocker switch.
- Turn ON the main power rocker switch while simultaneously pressing down the encoder knob and hot water button until the Group 1 display reads Preset Done.
- Release the buttons.
- Power cycle using main power rocker switch.
- Upon power cycling the machine. Group 1 will briefly prompt the firmware version and a blank serial number.
Step 3:
Re-enter the information:
- Serial Number
- Number of Groups
- Brew Temperature Offsets
- Flowmeter Offset
- Steam LP: FlowMeterRate G
Questions or concerns? Please contact: support@slayerespresso.com