RTD Test, Single Group
This procedure tests the resistance of the RTD. The RTD measures the temperature of the brewing group. As the machine fluctuates in temperature, the resistance will change sending a signal to the board to heat or not heat the machine. Resistance on the voltage meter is measured in ohms.
Tools Needed:
Multi Meter
Time Needed: 10 min
Part Tested: 86004-20080 Single Group RTD W/ Molex
Procedure
Locate the wiring bundle to the brew group, the white wire with a red and white connection is the RTD. Disconnect the Molex connection (white connector)
Set the multimeter to Ohms, typically signified by the omega symbol.
Insert the probes of the multimeter into the male Molex connection, one in each port of the RTD Molex, and measure the resistance. The resistance should be 500 Ohms at room temperature. If the machine is heated up the range will be 530-550 ohms
If the RTD is outside of the specs listed, the part has failed and will need to be replaced.
Related Articles
RTD Test, Single Group
RTD Test, Single Group Slayer recommends that all service be performed by an experienced Slayer Espresso trained technician. Time Needed: 10 Minutes Part Tested: 86004-20080 Single Group RTD W/ Molex Parts can be requested from our Customer Logistics ...
24 Volt Power Supply Test
24 Volt Power Supply Test Slayer recommends that all service on electrical parts be performed by an experienced Slayer Espresso trained technician. Time: <5 minutes Tools: #2 Philips head screwdriver Voltmeter Servicing, operating, and installing ...
Replacement of RTD, Espresso Line
Replacement of RTD Espresso Line Tools Needed: Philips Screwdriver, 12mm Wrench, Teflon Tape Time Needed: 30min Shut off water Turn off power Remove screws on group cover Remove Group Cover The RTD has the white wire running off of it Follow the ...
RTD Test, V3
This procedure tests the resistance of the RTD. The RTD measures the temperature of the brewing group. As the machine fluctuates in temperature, the resistance will change sending a signal to the board to heat or not heat the machine. Resistance on ...
Error Code Identification - Espresso Single Group
Espresso Single Group Error Code Identification SLAYER Espresso Single Group error codes correlate directly to the affected hydraulic or electrical circuit. Error codes help isolate further troubleshooting measures. When present on the display, error ...