Panel Alignment - Single Group

Panel Alignment - Single Group


Slayer Single Group Panel Alignment - 2023 Model



Slayer recommends that all service be performed by an experienced Slayer Espresso trained technician. 

Purpose:
Re-align side panels to base plate. Commonly caused by rough transit or loose bolts.

Symptoms:
Front panel sitting proud of side panel contours. Rear panel appears uneven. 

Time:
1hr

Parts:

Tools: 
  1. Hex
    1. M5
    2. 3/16"
  2. Wrench
    1. 7/16"
  3. Socket
    1. 7/16"
  4. #2 Phillips Screwdriver
Step 1:
Place machine on block.
Remove cup tray, front upper panel, and rear panel.

Step 2:
Loosen hex bolts labeled 1 on image below. Followed by removing the outside cosmetic hub by loosening arrow 2 (Interior recess).
Be sure to hold cosmetic hub while loosening bolt.


Step 3: 
Using a 7/16 socket, lightly loosen 4 nuts below and adjust side panel as necessary to be flush with base plate.
This should clear up the front panel resting proud of the side panels.


Step 4:
Once side panels are aligned with base plate, tighten the four (4) bolts in a radial pattern to ensure proper fit.
Reassemble rear and front upper panel.

Slight adjustments may be required for all panels to ensure a clean alignment.



Questions or concerns? Please contact support@slayerespresso.com

    • Related Articles

    • Panel Installation - Single Group

      Single Group Panel Installation Slayer recommends that all service be performed by an experienced Slayer Espresso trained technician. Objective: Install and remove panels for maintenance, service, and panel replacement. Please contact Slayer Tech ...
    • Neck Cover Alignment - Universal

      Slayer Espresso, Single Group, & Steam Series Neck Cover Alignment All Slayer models feature a fabricated stainless neck cover designed to rest between the upper front panel and group head cover. Free floating and adjustable, the neck cover protects ...
    • Diagnosing SSR Single Group

      Diagnosing SSR Single Group Tools Needed: Voltage meter Remove cup tray and back panel of the machine, being aware of the ribbon cable attached to the control board. Leave the ribbon cable attached and lean the back panel on the machine giving you ...
    • Replacing Circuit Board Single Group

      Replacing Circuit Board Single Group   Tools Needed: #2 phillips head screw driver, #0 phillips head screw driver. Time Needed: 10 minutes Unplug machine and turn off water Remove Cup Tray Remove the two screws on the back panel under where the cup ...
    • Testing No Power, Single Group

      Testing No Power, Single Group Time Needed: 10 Minutes Parts Needed: None Tools Needed: #2 Phillips Screwdriver Multi Meter Circuit Board Reference #1 - Main power - 24v DC from power supply #2 - Relay #3 - Display ribbon cable #4 - Transducer #5 - ...