Single Group Board Test

Single Group Board Test






With the ribbon cable (top right) being 1. Following counterclockwise to the last connection (bottom right) being 9.





Unplug the machine from the power source


Unplug all connections except 1 and 3.


Plug the machine back into the power source


One by one, plug in connections : 2,4,6,7,8,5


Each time a connection is plugged in, check to see if the machine is on.  


Advise if and when the machine turns off.


    • Related Articles

    • RTD Test, Single Group

      RTD Test, Single Group This procedure tests the resistance of the RTD. The RTD measures the temperature of the brewing group. As the machine fluctuates in temperature, the resistance will change sending a signal to the board to heat or not heat the ...
    • Single Group Board Power Test

      Unplug the machine.  Remove the back panel, being aware of the ribbon cable attached to the screen.  Unplug all the plugs except #1 and #3.  Follow #3 up to the screen and make sure it is attached to the screen, set the back panel to the left side of ...
    • Single Group (Classic) Electronics Identification Diagram

      Single Group Classic Electronics Diagram Slayer Single Groups manufactured before January 2020. 1. Display Ribbon Cable 7. Group Cap Magnet Switches 2. Relay Harness 8. Steam Tank Level Probe 3. 24v DC Power 9. Transducer 4. Solenoids 10. SSR Steam ...
    • Eltek Transducer Retrofit - Single Group Classic

      Slayer Single Group (Classic) transducer retrofit guide Slayer recommends that all service be performed by an experienced Slayer Espresso trained technician. Objective: Update legacy Single Group machines to current Eltek transducer assembly. ...
    • Error Code Identification - Espresso Single Group

      Espresso Single Group Error Code Identification SLAYER Espresso Single Group error codes correlate directly to the affected hydraulic or electrical circuit. Error codes help isolate further troubleshooting measures. When present on the display, error ...