Hard Reset - Single Group
Hard Reset, Single Group
Step 1:
- Press circle to enter programming
- Scroll to Advanced Settings and circle to enter
- Scroll to menu option Save/Restore settings, press circle to enter
- Arrow up to Reset Factory Default
- Press circle, arrow to yes, press circle
- Arrow up to Reset Factory Tuned
- Press circle, arrow to yes, press circle
- Actuate group paddle to go to main screen.
- Unplug machine for 10 seconds
- Plug machine back in.
Step 2:
- Press circle to enter programming
- Scroll to Advanced Settings
- Select menu option Heater Control On/Off
- Turn on brew boiler
- Turn on steam boiler
- Actuate group paddle to go to main menu
- Machine should heat up in 20-30 min.
Step 3:
- Once machine is heated up, you'll need to set the pump pressure again.
- Press circle to enter programming
- Scroll to Brew Pump Pressure
- Press circle to bracket Pump Percentage
- Insert blind portafilter
- Turn on full brew
- Increase percentage until the bar pressure on the gauge reads 10 bar
Related Articles
Reset Factory Default - Steam Series
Reset Factory Default - Steam X, LP, & EP SLAYER recommends all service be performed by an experienced SLAYER Espresso trained technician. For a technician reference near you, please contact SLAYER Support at (206)-284-7171 (#1 in Directory) or email ...
Error Code Identification - Espresso Single Group
Espresso Single Group Error Code Identification SLAYER Espresso Single Group error codes correlate directly to the affected hydraulic or electrical circuit. Error codes help isolate further troubleshooting measures. When present on the display, error ...
Display Operation - Single Group
Slayer Single Group Display Operation Objective: Navigate touch operations of LCD display. Parts: 99004-60120 DISPLAY ASSEMBLY, HOME Tools: Pad of your thumb. The operation of the single group display is best described in the video below. Using as ...
Hard Reset, Steam X
Steam X Hard Reset This hard reset will send the brain back to factory settings. This means it will lose all information such as serial number and offsets. Therefore, before doing this procedure, record serial number, brew offsets and flow meter ...
Single Group Pump Reset
Unplug the machine. Take the cup tray off. Remove the back panel. Follow the wire from the pump to the board. Below is a photo of which port the pump plug goes in. Unplug the pump plug and leave unplugged for two minutes. Plug the pump back in, ...