Hard Reset, Steam X

Hard Reset, Steam X

 
Steam X Hard Reset



This hard reset will send the brain back to factory settings. This means it will lose all information such as serial number and offsets.
Therefore, before doing this procedure, record serial number, brew offsets and flow meter offsets.
Machine Information:
  1. From the barista dashboard, scroll to Switch Off.
  2. While on the OFF screen. Press and hold Group 1 encoder knob for 12 seconds. This enters into the deep menu.
  3. Take note of the serial number unless already recorded.
  4. Press the encoder knob to initialize the machine from "Off" to the main barista menu.
  5. Press and hold the encoder knob for 5 seconds until the secondary menu appears. ("Heater Control" will be displayed.)
  6. Record the following information: 
    1. Celsius or Fahrenheit
    2. Brew Temp Offset
    3. Max Pressure:  2Bar or 100 PSI. (Eltek is “2Bar”, Honeywell is “100 PSI”)
    4. Brew Parameters
    5. Flow Meter Offsets
  7. When the information is recorded, turn off the low voltage switch (power switch)
  8. Press the hot water button and the encoder knob at the same time. With both these button pressed, turn on the machine.
    The machine should read 'preset done'.
  9. Power Cycle
  10. Re-enter machine information recorded in previous steps, with the addition of "Number Of Groups"




 Questions or concerns? Please contact: support@slayerespresso.com



    • Related Articles

    • Reset Factory Default - Steam Series

      Reset Factory Default - Steam X, LP, & EP Slayer recommends that all service be performed by an experienced Slayer Espresso trained technician. Resetting to factory default will reset all personal settings. Scroll through the menu settings and record ...
    • Hard Reset - Single Group

      Hard Reset, Single Group Step 1: Press circle to enter programming Scroll to Advanced Settings and circle to enter Scroll to menu option Save/Restore settings, press circle to enter Arrow up to Reset Factory Default Press circle, arrow to yes, press ...
    • Password Reset - Steam Series

      Password Reset - Steam LP & EP Advanced Menu: Steam LP: 7 7 7 7 7 7 7 (seven 7's) Steam EP: SEATTLE7 Default Password: Manager - 1 1 1 1 Advanced - 1 2 3 4 Step 1: From the Menu press the encoder knob to jump to Enter Password, or scroll to Enter ...
    • Program and Calibrate Volumetrics - Slayer Steam X

      Program and Calibrate Slayer Steam X Volumetrics Time: 10 minutes Tools: Espresso Scale Preparation: Calibrating volumetrics requires considerate espresso preparation. External factors such as coffee, dose, and tamp equally contribute to the quality ...
    • Steam Actuator Adjustment - Steam Series

      Adjusting Steam Actuator - Steam Series Objective: Slayer magnetic steam actuators have two positions: Up is a rinse that should bounce back to the off position. On is a continuous steam actuation. The actuator should index in the center and now ...