Universal
Neck Cover Alignment - Universal
Slayer Espresso, Single Group, & Steam Series Neck Cover Alignment All Slayer models feature a fabricated stainless neck cover designed to rest between the upper front panel and group head cover. Free floating and adjustable, the neck cover protects ...
Slayer Torque Specifications
Slayer Espresso & Steam Series Slayer recommends that all service be performed by an experienced Slayer Espresso trained technician. Universal Brew and Steam Tank Elements 18 Foot Lbs Espresso V3 Pre-Heat Element 32 Foot LBS 6 wraps of Teflon tape ...
Compression Fitting Guide - Universal
Slayer V3, Single Group, and Steam Series Field guide for installing compress-align compression fittings to copper lines. Slayer recommends that all service be performed by an experienced Slayer Espresso trained technician. Compress-Align Step 1: ...
Brew Group Actuator Rebuild - Universal
Group Actuator Maintenance Time: 5-10 minutes Tools: #3 Philips screwdriver Flathead screwdriver #6 hex key Parts: 46000-53070 Gasket, Teflon 10000-16210 Spacer Food grade lube Procedure Step 1: Remove group cover by loosening the three Philips ...
Group Cap Rebuild, Universal
Click the link below to view video: Group Cap Rebuild
Assembling Spouts On Portafilter, Universal
Time Needed: <5 Minutes Parts Needed: 46000-56120 Double Spout, Spouts Only 46000-56131 Portafilter Body, Body Only Tools Needed: Screw Driver Step 1: Insert driver into spouts of portafilter Step 2: Rotate spouts using leverage from driver until ...
Disassembly of Vacuum Breaker and Inspection of Internal Seat
Disassembly of Vacuum Breaker and Inspection of Internal Seat Time Needed: 30 Min Tools Needed: Two Crescent Wrenches Warning: Turn off machine and purge the steam before completing this action. Once Steam is purged and vacuum breaker has fallen, ...
Replacing High Limit Switch (limit thermostat)
Tools Needed: #2 screwdriver Time Needed: Less than 10 minutes Remove top front panel Remove wires from high limit switch Remove the high limit switch. The high limit switch is a brass fitting that screws into stainless steel. It is very fragile and ...
Boiler Sediment Removal Procedure
Boiler Sediment Buildup Removal Procedure Materials: Scale Kleen, Tub for soaking boiler, rubber gloves, tools, 5 gallons of hot water, baking soda. Remove boiler from machine Tip: Before you begin, take reference pictures for reassembly Remove ...
Slayer Steam Panel Removal and Installation
Slayer Steam Panel Removal and Installation Tools Needed: crescent wrench, #2 screwdriver, #4 allen key Time: 30-45 minutes Turn off water and power, unplug the machine Remove the top cup tray Remove panel screws while supporting the panel. Set ...
Hot Water Mix Valve Troubleshooting
Slayer Steam X, LP, EP, & Espresso V3 Remove Hot Water Mix valve to diagnose fault or replace assembly. Troubleshooting leaking mix valve may be accomplished while assembly is on the machine. Common Causes: Particles (scale, sediment) or worn ...
Replace Vacuum Breaker, V3
What is a Vacuum Breaker? A vacuum breaker is a valve on the steam tank which seals after enough pressure has built up. As the name describes, the vacuum breaker creates a vacuum once sealed to prevent any back flow from steam steam wand when going ...
Portafilter Head Replacement
Portafilter Handle Removal Procedure Install portafilter into the group head Grip the handle tightly and rotate in a counter clockwise direction Remove old portafilter head from group Install new portafilter head Install the new portafilter handle ...
24 Volt Power Supply Test
24 Volt Power Supply Test Slayer recommends that all service on electrical parts be performed by an experienced Slayer Espresso trained technician. Time: <5 minutes Tools: #2 Philips head screwdriver Voltmeter Servicing, operating, and installing ...
Resistance Specifications - Universal
Resistance Specifications Espresso V3, Single Group, & Steam Series SLAYER recommends that all service be performed by an experienced SLAYER Espresso trained technician. Temperature Probe Resistance Espresso V3 Thermocouple Resistance Room Temp: ...
Adjusting Brew Actuator Tension - Universal
Adjusting Tension of Slayer Brew Actuators Time: <5 minutes Tools: Flathead screwdriver #6 hex key Procedure Step 1: Remove lock screw. Step 2: Insert hex key and adjust tension. Clockwise is tight, counter-clockwise is loose. Be careful not to ...