Barrel Switch Troubleshooting



Objective:
Test magnetic barrel switches to diagnose steam solenoid issues.  

Time:
15-20 minutes

Tools:
#2 Philips Head Screw Driver
Multimeter

Adjusting Sensitivity

Steam barrel switches are threaded into the housing and are adjustable by screwing in or out. If it's not adjusted properly, it could affect the response of the actuator. 

  1. If your steam solenoid is engaging in the "Off" position, try threading it clockwise so the switch makes better contact with the magnetic field.

  2. If the steam solenoid isn't engaging when actuating, try unthreading it counter-clockwise so the switch moves further away from the magnet. 


If the switch doesn't respond despite adjustment, you'll need to test the functionality.

Testing Functionality

Step 1:

Step 2:
Remove the bottom front panel, being sure to disconnect the LED group lights. 

Step 3:
To identify the correct barrel is being used, test the barrel's continuity with a multimeter. Steam barrel switches are N/C (normally closed). It should only be active and have continuity when a magnet is not present. Conversely, there is no continuity when a magnet is present.
Please note, to test this properly you need to remove the barrel from the assembly.





The continuity should reliably change based on the presence of the magnet. 






    Questions or concerns? Please contact: support@slayerespresso.com

      • Related Articles

      • Group Magnet Switch Troubleshooting - Steam Series

        Group Mag Switch Troubleshooting Steam LP & Steam X Objective: Inside the group head is a tongue with a magnet installed on it. This magnet comes in contact with the magnetic reed switches which send signals to the control board for brewing. ...
      • Group Magnet Switch Troubleshooting - Espresso Series

        Group Mag Switch Troubleshooting - Espresso V3 & Single Group SLAYER recommends all service be performed by an experienced SLAYER Espresso trained technician. For a technician reference near you, please contact SLAYER Support at (206)-284-7171 (#1 in ...
      • Pre-Infusion Solenoid Troubleshooting - Steam LP

        Pre-Infusion Solenoid Troubleshooting - Steam LP SLAYER recommends all service be performed by an experienced SLAYER Espresso trained technician. For a technician reference near you, please contact SLAYER Support at (206)-284-7171 (#1 in Directory) ...
      • Error Code Identification - Steam Series

        Steam X, EP, & LP Error Code Identification SLAYER Steam Series feature error codes which correspond to the affected hydraulic or electrical circuit. There error codes help isolate further troubleshooting measures. Error codes replace the temperature ...
      • Steam Actuator Stack - Espresso Series

        Actuator Stack - Espresso V3 & Single Group SLAYER recommends all service be performed by an experienced SLAYER Espresso trained technician. For a technician reference near you, please contact SLAYER Support at (206)-284-7171 (#1 in Directory) or ...