Objective:
The Love Controller on the SLAYER V3 is the PID controller for both the pre-heat (SD1/Out1) and steam tanks (SD2/Out2). This guide outlines wiring connections, programing, and troubleshooting.

Programing & Settings:

Parts:
30000-20220 LOVE CONTROLLER, PREHEAT AND STEAM
Scroll for legacy wiring configuration.

Probe Inputs:
1 -SD1 - Signal from the preheat thermocouple. (T1: orange band)
2 - SD2 - Signal from steam tank thermocouple. (T2: red band)
3 - Common

Power Supply:
4 - Pre-Heat & Steam Tank SSR through power bundle.
5 - Power Supply (Jumper to 8 & 11)

Outputs:
7 -  Out1- Signal to Pre-Heat SSR
8 - Power Supply Jumper
10 - Out2 - Signal to Steam Tank SSR
11 - Power Supply Jumper





Legacy Configuration:
Questions or concerns regarding  love controller wiring configuration? Please contact SLAYER Tech Support before proceeding!

Probe Inputs:
1 -SD1 - Signal from the preheat thermocouple.
2 - SD2 - Signal from steam tank thermocouple. 
3 - Common

Power Supply:
4 - Power Supply (Jumper to 7 & 10)
5 - Power Supply, Pre-Heat & Steam Tank SSR through power bundle.
Additional common wires may be present at 4 and 5.
Outputs:
7 - Power Supply Jumper
8 - Signal to Pre-Heat SSR
10 - Power Supply Jumper
11 - Signal to Steam Tank SSR



Troubleshooting:
There is no error prompt for incorrect wiring or crossed thermocouple connections. Symptoms caused by crossed wires include under or overheated steam and pre-heat tanks. 



Questions or concerns? Please contact: support@slayerespresso.com
    • Related Articles

    • Love Control Settings - Slayer V3

      Love Control Settings & UI Navigation - Slayer V3 Slayer recommends that all service be performed by an experienced Slayer Espresso trained technician. Objective: The Love Controller manages the heating circuit for the Preheat and Steam tanks on the ...
    • Error Code Identification - Love Controller

      Love Control Errors Slayer recommends that all service be performed by an experienced Slayer Espresso trained technician. Objective: The Love Controller on the SLAYER V3 is the PID controller for both the pre-heat (SD1/Out1) and steam tanks ...
    • Slayer Board Wiring - Steam Series

      Control board wiring diagrams for Slayer Steam Series. These schematics can be used for identifying control inputs and for reference when replacing the board. *Steam X board wiring can be referenced by the Steam EP drawing.* Questions identifying a ...
    • Power Harness Wiring - Slayer V3

      Power Harness Wiring - Slayer Espresso V3 Slayer recommends all service be performed by an experienced Slayer Espresso trained technician. Harness wiring positions for the main Molex connection between the power terminal and electronics panel. Wire ...
    • PID Error Code Identification & Wiring - Slayer V3

      PID Error Code Identification and Wiring Diagram - Espresso V3 Slayer recommends all service be performed by an experienced Slayer Espresso trained technician. PID or Proportional–Integral–Derivative controller (PID controller or three term ...