Love Control Wiring - SLAYER V3
SLAYER recommends all service be performed by an experienced SLAYER Espresso trained technician. For a technician reference near you, please contact SLAYER Support at (206)-284-7171 (#1 in Directory) or email support@slayerespresso.com.
Objective:
The Love Controller on the SLAYER V3 is the PID controller for both the pre-heat (SD1/Out1) and steam tanks (SD2/Out2). This guide outlines wiring connections, programing, and troubleshooting.
Programing & Settings:
Parts:
30000-20220 LOVE CONTROLLER, PREHEAT AND STEAM
Scroll for legacy wiring configuration.
Probe Inputs:
1 -SD1 - Signal from the preheat thermocouple. (T1: orange band)
2 - SD2 - Signal from steam tank thermocouple. (T2: red band)
3 - Common
Power Supply:
4 - Pre-Heat & Steam Tank SSR through power bundle.
5 - Power Supply (Jumper to 8 & 11)
Outputs:
7 - Out1- Signal to Pre-Heat SSR
8 - Power Supply Jumper
10 - Out2 - Signal to Steam Tank SSR
11 - Power Supply Jumper
Probe Inputs:
1 -SD1 - Signal from the preheat thermocouple.
2 - SD2 - Signal from steam tank thermocouple.
3 - Common
Power Supply:
4 - Power Supply (Jumper to 7 & 10)
5 - Power Supply, Pre-Heat & Steam Tank SSR through power bundle.
Additional common wires may be present at 4 and 5.
Outputs:
7 - Power Supply Jumper
8 - Signal to Pre-Heat SSR
10 - Power Supply Jumper
11 - Signal to Steam Tank SSR
There is no error prompt for incorrect wiring or crossed thermocouple connections. Symptoms caused by crossed wires include under or overheated steam and pre-heat tanks.