Love Control Wiring - V3

Love Control Wiring - V3


Love Control Wiring - SLAYER V3



AlertSLAYER recommends all service be performed by an experienced SLAYER Espresso trained technician. For a technician reference near you, please contact SLAYER Support at (206)-284-7171 (#1 in Directory) or email support@slayerespresso.com.

Objective:
The Love Controller on the SLAYER V3 is the PID controller for both the pre-heat (SD1/Out1) and steam tanks (SD2/Out2). This guide outlines wiring connections, programing, and troubleshooting.

Programing & Settings:

Parts:
30000-20220 LOVE CONTROLLER, PREHEAT AND STEAM
Info
Scroll for legacy wiring configuration.

Probe Inputs:
1 -SD1 - Signal from the preheat thermocouple. (T1: orange band)
2 - SD2 - Signal from steam tank thermocouple. (T2: red band)
3 - Common

Power Supply:
4 - Pre-Heat & Steam Tank SSR through power bundle.
5 - Power Supply (Jumper to 8 & 11)

Outputs:
7 -  Out1- Signal to Pre-Heat SSR
8 - Power Supply Jumper
10 - Out2 - Signal to Steam Tank SSR
11 - Power Supply Jumper





Legacy Configuration:
Warning
Questions or concerns regarding  love controller wiring configuration? Please contact SLAYER Tech Support before proceeding!

Probe Inputs:
1 -SD1 - Signal from the preheat thermocouple.
2 - SD2 - Signal from steam tank thermocouple. 
3 - Common

Power Supply:
4 - Power Supply (Jumper to 7 & 10)
5 - Power Supply, Pre-Heat & Steam Tank SSR through power bundle.
Info
Additional common wires may be present at 4 and 5.
Outputs:
7 - Power Supply Jumper
8 - Signal to Pre-Heat SSR
10 - Power Supply Jumper
11 - Signal to Steam Tank SSR



Troubleshooting:
There is no error prompt for incorrect wiring or crossed thermocouple connections. Symptoms caused by crossed wires include under or overheated steam and pre-heat tanks. 



Questions or concerns? Please contact: support@slayerespresso.com
    • Related Articles

    • Love Control Settings - V3

      Love Control Settings & UI Navigation - SLAYER V3 SLAYER recommends all service be performed by an experienced SLAYER Espresso trained technician. For a technician reference near you, please contact SLAYER Support at (206)-284-7171 (#1 in Directory) ...
    • Error Code Identification - Love Controller

      Espresso V3 Love Control Errors SLAYER recommends all service be performed by an experienced SLAYER Espresso trained technician. For a technician reference near you, please contact SLAYER Support at (206)-284-7171 (#1 in Directory) or email ...
    • Slayer Board Wiring - Steam Series

      Control board wiring diagrams for Slayer Steam Series. These schematics can be used for identifying control inputs and for reference when replacing the board. *Steam X board wiring can be referenced by the Steam EP drawing.* Questions identifying a ...
    • Power Harness Wiring - V3

      Power Harness Wiring - Espresso V3 SLAYER recommends all service be performed by an experienced SLAYER Espresso trained technician. For a technician reference near you, please contact SLAYER Support at (206)-284-7171 (#1 in Directory) or email ...
    • PID Error Code Identification & Wiring - V3

      PID Error Code Identification and Wiring Diagram - Espresso V1-3 SLAYER recommends all service be performed by an experienced SLAYER Espresso trained technician. For a technician reference near you, please contact SLAYER Support at (206)-284-7171 (#1 ...