EP
Verifying Correct Transducer Setting EP
Verifying Correct Transducer Setting Time: 5 min Tools: none Scroll to "Switch Off", press the toggle, scroll to yes and switch off. From the Switched Off menu press and hold the toggle for 12 seconds Once in the production menu, scroll to Xducer ...
Steam EP Drip Tray Bracket
Tools Needed: #2 screwdriver, 7/16 wrench. #4 allen wrench Time Needed: 30-45 min Turn off machine and unplug Raise the hood. https://desk.zoho.com/portal/slayer/kb/articles/raising-hood-of-slayer-steam Remove bottom front panel. 4 screws on a 3 ...
Hard Reset Procedure Steam EP
Hard Reset Procedure Steam EP Turn off breaker switch, and main power Hold the water button and the toggle button at the same time Have someone switch on main power, hold until you read "Preset Done" Turn off the main power, wait 10 seconds, turn on ...
Steam EP Moving Steam Boiler to fill off Pump
The steam EP steam boiler fills with line pressure. We did this to allow the machine to fill and not rob brew pressure while the machine is brewing. The machine can be configured to pull off the pump, for example if you wanted to use a water bottle. ...