Stuck Bypass Adjustment Single Group Rotary Pump
Time Needed: 10 Min Tools Needed: Adjustable wrench Turn off machine Turn off water Use a screwdriver to adjust the screw 1/2 way out of the carriage. With adjustable wrench remove the fitting, be cautious as there is a spring and the parts could ...
Single Group Display Removal and Replacement
Single Group Display Removal and Replacement Time Needed: 15 Min Parts Needed: Single Group Screen Tools Needed: #2 Screwdriver, 5/64 Allen Step 1: Turn off machine and unplug Step 2: Remove cup tray Step 3: Remove back panel, two screws under where ...
Single Group Board Power Test
Unplug the machine. Remove the back panel, being aware of the ribbon cable attached to the screen. Unplug all the plugs except #1 and #3. Follow #3 up to the screen and make sure it is attached to the screen, set the back panel to the left side of ...
Single Group Pump Reset
Unplug the machine. Take the cup tray off. Remove the back panel. Follow the wire from the pump to the board. Below is a photo of which port the pump plug goes in. Unplug the pump plug and leave unplugged for two minutes. Plug the pump back in, ...
Hard Reset - Single Group
Hard Reset, Single Group Step 1: Press circle to enter programming Scroll to Advanced Settings and circle to enter Scroll to menu option Save/Restore settings, press circle to enter Arrow up to Reset Factory Default Press circle, arrow to yes, press ...