Universal
Uncrating Slayer Steam
Just got your machine? Excited to bust it out of the crate and start brewing espresso? The guide below will walk you through uncrating your Slayer Steam. Slayer Steam
Blending Hot Water Mix Valve, Steam Series
Blending Mix Valve on Slayer Steam Series Tools Needed: Large flat head screwdriver, phillips head screwdriver, or a multi screwdriver Time Needed: 5-10 minutes Step 1: Remove cup tray and left side panel and set aside. Step 2: Locate Hot water mix ...
Wing Replacement, Steam Series
Wing Replacement Time Needed: 1 hour Tools Needed: #10 allen wrench, 10mm socket driver, Torque wrench set to 40 ft pounds, #1 phillips head screw driver Shut down machine and turn off water, disconnect from power Elevate machine, We use a 1x6 ...
Giggleur Insert Procedure, Steam Series
Time: 15 minutes Tools Needed: #6 Allen Wrench, #3 screwdriver, Turn off Machine, Turn off the water to the machine Open drain valve for corresponding group. (V3, insert high temp tubing into the drain port) Remove Group Cover Using #6 allen key ...
Resetting Password on Steam Models
Resetting Steam LP & EP Passwords Use this guide if you have set your manager and advanced passwords and forgotten them. We have programmed in an override password for each model. Steam LP: (seven 7's) - 7 7 7 7 7 7 7 Steam EP: SEATTLE7 Enter this ...
Steam Actuator Adjustment - Steam Series
Adjusting Steam Actuator - Steam Series Objective: Slayer magnetic steam actuators have two positions: Up is a rinse that should bounce back to the off position. On is a continuous steam actuation. The actuator should index in the center and now ...
Slayer Steam Hot Water Button Not Working
Slayer Steam Hot Water Button Not Working 1. Verify that the button is connected 2. Verify the button is not loose from the assembly 3. Raise the hood of the machine 4. Verify the button is seated properly in the carriage
Checking Brew Solenoid Boot for Operation
Checking Brew Solenoid Boot for Operation Tools needed: Voltage meter, small pick set, small screwdriver set. First I would like to check if the brew solenoid is being sent the correct information. Set your voltage meter to 24v DC. Place one probe ...
Cleaning Flow Meter, Steam
What is a flow meter? A flow meter is a component in the machine which,using magnets, records how much water has passed through and sends the information to the board. The board then takes the information given and displays the value in grams on the ...
Draining Tanks, Steam
Draining Tanks, Steam Series Time Needed: 10-15 minutes Parts Needed: None, There is an internal drain manifold which will exit the drain hose. Tools Needed: None Step 1: Turn off dedicated water source to the machine. Turn off breaker switch and ...
Catch Test, Steam
Catch Test What does a catch test tell us? A catch tests tells us a lot of information in a little amount of time. Mainly if there is any restriction of flow anywhere in the brew system. If we know the flow path is clear, we can troubleshoot ...
Removing Upper Front Panel - Steam Series
Raising The Hood Objective: Remove upper front panel in order to perform service. Time: 30 minutes Tools: #2 Philips Head Screw Driver 1/2" Wrench Step 1: Turn off machine and unplug from power. Shut off water feed. Step 2: Remove the cup tray panels ...
Error Code Identification - Steam Series
Steam Line Errors Brew Temp AL1: Group temp probe is interrupted or disconnected. Stops heating group. Check that the thermistor is connected, Molex pins are in place and wires are snug. Brew Temp AL2: Group temp probe has a short circuit. Stops ...
Setting Pump and Regulator Assembly - Slayer Steam X
Setting Pump & Regulator - Steam X Objective: Steam X was designed with a unique pump assembly that featured an in-line pressure regulator for the brew circuit. This guide will demonstrate how to calibrate this assembly. Time: 15 minutes Tools: ...